Product Profile
The HT8000 series of high voltage differential probes utilize a differential input mode and are mainly used in
The HT8000 series of high voltage differential probes are designed for use in applications where high voltage floating ground measurements are required.
The HT8000 series of high voltage isolation probes are available in 1/50 and 1/500 attenuation steps.
The differential mode measurement ranges are 130V (DC + peak AC) and 1300V
(DC + peakAC) respectively.
The high voltage isolation probes are equipped with an over-range alarm, indicated by a red LED.
LED indication.
This series of high voltage isolation probes has a small and beautiful appearance, rugged structure, and high stability and reliability.
They offer high stability, reliability and accuracy.
Application Examples
■Floating Ground Voltage Measurement
■Switching power supply design
■Inverters, UPS power supplies
■Frequency converters
■Electronic ballast design
■Induction heating, induction furnace
■Electrical experiment
■Power electronics and power transmission experiments, etc.
■Strong or high-voltage isolation measurements
■Power conversion and other related design
■Welding, plating power supply
■Inverter appliances
■Motor drive design
■ CRT monitor design
■ Low-voltage electrical testing
Key skill indicators
|
Electrical Performance
|
|
Model
|
HT8050
|
HT8100
|
|
Bandwidth(-3dB)
|
50MHz
|
100MHz
|
|
Rise Time
|
7 ns
|
3.5ns
|
|
Accuracy
|
±2%
|
|
Attenuation Ratio
|
1/50, 1/500
|
|
Input Impedance
|
Single-ended to ground: 4MΩ
Between two inputs: 8MΩ
|
|
Input Capacitance
|
Single-ended to ground: 7pF
Between two inputs: 3.5pF
|
|
Maximum Difference
|
1/50: 130V (DC + peak AC)
1/500: 1300V (DC + peak AC)
|
|
Measured Voltage
|
1000Vans, CATII
600Vrms,
CATlII
|
|
Maximum common mode
|
1/50: ≤ 1.5mVnns
1/500: ≤ 1mVrms
|
|
Input Voltage
|
±1%
|
|
Noise
|
20ns±1ns
|
|
Linearity
|
DC: ≥80dB
100Hz: ≥60dB
1MHz: ≥50dB
|
|
Delay Time
|
1/50: 140V ±4V (DC + peak AC)
1/500: 1400V
± 4 0V (DC + peak AC)
|
|
CMRR
|
DC9V, 1000mA
|
|
Over Range Alarm
|
AC 100-240V, 50〜60Hz
|
|
Voltage
Threshold
|
|
Power Adapter
|
Approx.
60cm Approx. 30cm
|
Approx. 60cm Approx. 30cm
|
|
Output Voltage
|
Approx.
90cm
|
|
Power Adapter
|
Approx.
85x40x13 (mm)
|
|
Input power supply
|
Approx.
160x45x13 (mm)
|
|
Mechanical Specifications
|
120x55x24 (mm)
|
|
Input Cable Length
|
160g
|
|
Output
Cable Length
|
|
Alligator Clip
|
0-40 ℃
|
|
Probe Hook
|
-10-45℃
|
|
Probe Body
|
85%RH
|
|
Mass
|
90%RH
|
|
Environmental Characteristics
|
3000m
|
|
Storage altitude
|
12000m
|
Usage
HT8000 series of high-voltage differential probe is very easy to use, but this product is not familiar with the user should first read this manual completely before starting the operation.
1, operation steps:
(1) Before use must first confirm that the power adapter input power voltage is normal.
(2) Before the test should estimate the measured voltage amplitude, if more than the voltage range, may damage the probe.
(3) The probe output BNC terminal connected to an oscilloscope or other measuring instruments, the input terminal and the choice of the test probe hook fixture is properly connected.
(4) The power adapter is connected to the probe, the green power (POWER) indicator light.
(5) According to the measurement voltage, select the appropriate range of the probe. When the measured voltage exceeds the range during the test, the red overload (OVER RANGE) indicator will light up, at this time should be immediately disconnected from the power supply and input.
6) According to the range of the probe initially set the attenuation ratio of the oscilloscope or other instruments. After starting the measurement and then according to the size of the measured signal, set the appropriate sensitivity of the oscilloscope.
7) Connect the object to be measured to start the measurement. Measurement, the probe body should be as far away as possible from the high-voltage pulse circuit to reduce the interference may cause errors.
8)After the test is completed, disconnect the power supply of the probe, first disconnect the two inputs from the measured point, and then unplug the input BNC terminal from the oscilloscope.
2. Precautions for use:
1) The input line should be wound as much as possible during the measurement, so that the noise can be better eliminated and the high-frequency response capability can be improved. The winding method is shown in the figure below:
2) Try not to extend the input line during the measurement, otherwise more noise will be introduced. If the input line must be extended, the length of the extension line should be the same. Moreover, the signal frequency of the measurement input should not exceed 10MHz, if the measurement signal frequency exceeds 10MHz, the error will be larger.
3) If you need to get high precision measurement results, you should carry out the measurement after the probe and the measuring instrument have been warmed up for 20 minutes.
3、Simple fault phenomenon and troubleshooting methods
|
Power
indicator does not light or blinks
|
Check the connection between the
power adapter plug and the power outlet or between the output and the probe;
test the power adapter for proper operation.
|
|
Measurement waveform is not
stabilized or error is noticeable.
|
Check the connections between the probe input and
the probe hook and between the probe hook and the point under test;
Check the connection between the probe output and
the oscilloscope;
Replacing the probe or measuring instrument for troubleshooting.
|
|
| |
|
|
| |
Payment
Accept payment for PayPal, WesternUnion, AliPay, MonetyGram, Sigue, Ria, Bank transfer & Credit card
Shipment
1. Airmail Registered: If you choose this option, your item will be sent by Singapore Post Airmail.
The delivery time varies from 15-45 days in different countries. For more details, you can visit:
https://track.4px.com/
|
2. DHL: If you choose this option, your item will be sent by DHL Express.
The delivery time is 3-5 working days. Before you choose this option, please check if your location is in the DHL Remote Areas list.
You can visit: https://www.dhl.com/
|
3. EMS: If you choose this option, your item will be sent by EMS Express.
The delivery time varies from 5-20 days in different countries.
For more details, you can visit: https://www.ems.com.cn/english
|
4. The shipping time may be delayed in busy seasons. For more details, please feel free to contact us.
|
We are only responsible for the tax/duty generated in China.
We are NOT responsible for any tax/duty in the destination countries.
If you need items to declare the value of the customs, please leave us message.
|
| |
|
| |
-
For IC Chipsets, there are generally two conditions
1) Original New: Original new chips are taken from manufacturer vacuum
sealed package with QA/QC markings, which means they are all well verified
and tested. The quality is superior.
2) Manufacturer Refurbished: Manufacturer refurbished chips are renewed and
tested by the manufacturer. They quality is secondary to original new chips.
-
You can check the items as soon as you receive them. If you find the
quality not acceptable, you can return them to us within 90 days, and we are
assured to replace them or refund you.
-
If the chips are already soldered and not in selling condition, they
cannot be returned.
-
We guarantee to ship out your order within 1-2 working days. If you do
not receive your purchase within 60 days, you can ask for a full refund.
|
| |
|
|